Series 58 Armour Coaxial Cable
Stranded Tin Copper Conductor
Solid Polyethylene Dielectric
95% Bare Copper Braid
LSOH Inner Jacket
80% Galvanized Steel Wire Braid
Armour
FRLSOH Outer Jacket
Cable Ordering Information
| Part Number |
Standards |
|
RG58C/U SWB FRLSOH
|
IEC 60332-1, IEC 60332-3C, IEC 60754
|
Characteristics
|
Material
|
Detail
|
inches
|
mm
|
|
Inner Conductor
|
Copper Covered Steel
|
0.023
|
19/0.18
|
|
Dielectric Inner Conductor
|
Solid Polyethylene Copper Covered Steel
|
0.146
|
2.95
|
|
1st Outer Conductor
|
95% Bare Copper Braid
|
0.170
|
3.75
|
|
Inner Jacket
|
Black LSOH
|
0.242
|
4.95
|
|
Armour
|
80% Galvanized Steel Wire
|
0.283
|
6.00
|
|
Outer Jacket Minimum Bend Radius
|
Black LSOH
|
0.362 3.0
|
8.00 76.20
|
|
Electrical Specifications
|
|
Characteristic Impedance, Ω
|
50 ± 3
|
|
|
Velocity of Propagation, %
|
66
|
|
|
Capacitance, Nominal
|
30.48 pF/ft
|
30.48pF/m
|
|
|
DC Resistance
|
Ω / kft
|
Ω / km
|
|
|
Inner Conductor
|
9.15
|
30
|
|
|
Attenuation, Maximum @ 68 °F (20 °C)
|
|
Frequency, MHz
|
dB / 100 ft
|
dB / 100 m
|
|
5
|
0..975
|
3.2
|
|
10
|
1.280
|
4.2
|
|
100
|
4.877
|
16.0
|
|
200
|
7.010
|
23.0
|
|
400
|
10.515
|
34.50
|
|
1000
|
18.287
|
60.0
|
|