Construction
|
|
2YCCY
|
|
2.25Ls/7.25Ds
|
|
RG214
|
|
Inner conductor
|
|
stranded copper wires, silver plated 7 x 0.75
|
|
mm
|
2.25 ±0.01
|
|
Insulation
|
|
PE
|
|
mm
|
7.25 ±0.05
|
|
1stbraid
|
silver plated, 94% optical coverage
|
|
2ndbraid
|
silver plated, 97% optical coverage
|
|
Sheath
|
|
LSOH
|
|
mm
|
10.80 ±0.15
|
Technical data
|
Designation
|
Type
|
Outer diameter
mm
|
Weight approx.
kg/km
|
Standard -delivery -length
m
|
Drum size
*PWD/ ring
|
Gross weight
kg
|
Copper
content
|
Tensile
force
N
|
|
2YCCY
|
2.25Ls/7.25Ds
|
10,8
|
200
|
1000/100
|
760/360/420
|
212/20
|
118
|
730
|
|
2YCCY
|
2.25Ls/7.25Ds **grau RL 30 dB
|
10,8
|
200
|
1000/100
|
760/360/420
|
212/20
|
118
|
730
|
|
2YCCY
|
2.25Ls/7.25Ds ***RL 32 dB
|
10,8
|
200
|
1000/100
|
760/360/420
|
212/20
|
118
|
730
|
|
2YCCY
|
2.25Ls/7.25Ds ***RL 36 dB
|
10,8
|
200
|
1000/100
|
760/360/420
|
212/20
|
118
|
730
|
*PWD (Plywood drum)
**RG214 with grey sheath and better Return Loss (30 dB up to 1 GHz)
***RG214 with better Return Loss (32 resp. 36 dB up to 1 GHz) and special customer sheath marking
Electrical properties
|
|
2YCCY
|
|
2.25Ls/7.25Ds
|
|
RG214
|
|
DC resistance
|
|
|
Inner conductor 1. screen 2. screen
|
Ω/km Ω/km Ω/km
|
5.7 6.2 6.2
|
|
Mutual capacitance
|
pF/m
|
100
|
|
Characteristic impedance
|
Ω
|
50 ± 2
|
|
Velocity ratio
|
%
|
66
|
|
Structural return loss
|
|
100 MHz
1GHz 3 GHz 5 GHz 11 GHz
|
dB
|
≥23 ≥20 ≥19 ≥18 ≥17
|
|
Maximum operating frequency
|
GHz
|
11
|
|
Attenuation at
|
|
|
50 MHz 400 MHz 1000 MHz 3000 MHz 11000 MHz
|
dB/100m
|
4.9 15.1 26.5 max. 91.6 max. 196.2
|
|
Maximum Power rating at (ambient + 25°C)
|
|
|
50 MHz 400 MHz 1000 MHz 3000 MHz 11000 MHz
|
Watts
|
1500 330 160 75 30
|
|
Operating voltage
|
kVrms
|
3.7
|
|
Test voltage
|
|
Inner-/outer conductor
|
kVrms
|
10.0
|
Mechanical properties
|
Operating temperature
|
- 40°C to 85°C
|
|
Installation temperature
|
- 15°C to 55°C
|
|
Minimum bending radius (during installation)
|
|
|
without load
|
5 x outer diameter
|
|
with load
|
10 x outer diameter
|
|
Fire propagation test
|
IEC 60332-1
IEC 61034
IEC 60754
|
|