2YCCH
|
|
2.25Ls/7.25Ds
|
|
RG 214 FRNC
|
|
Inner conductor
|
stranded copper wires silver plated7x0.75
|
|
mm
|
2.25
|
|
Insulation
|
PE
|
|
mm
|
7.25 ± 0.18
|
|
1st braid
|
copper wire braid silver plated
|
|
mm
|
8.0
|
|
2nd braid
|
copper wire braid silver plated
|
|
mm
|
8.8
|
|
Inner Sheath
|
Flame Retardant Non Corrosive Copolymer
|
|
mm
|
10.8 ± 0.18
|
|
Plain Copper Wire Braid 80% Coverage (12x6x0.3)
|
12.3 ± 0.25
|
|
Outer Sheath
|
Flame Retardant Non Corrosive Copolymer
|
|
mm
|
14.5 ± 0.50
|
Mechanical properties
|
Operating temperature
|
- 40°C to 85°C
|
|
Installation temperature
|
- 15°C to 55°C
|
|
Minimum bending radius (during installation)
|
|
without load
|
5 x outer diameter
|
|
with load
|
10 x outer diameter
|
|
Fire propagation test
|
acc. to IEC 60332-3
|
|
Smoke density
|
acc. to IEC 61034-2
|
|
Corrosivity of fire gases
|
acc. to IEC 60754-1/2
|
Electrical properties
| |
|
|
|
2YCCH
|
|
2.25Ls/7.25Ds
|
|
RG214 FRNC-B
|
|
DC resistance
|
|
Inner conductor
1st braid
2nd braid
|
Ω/km
Ω/km
Ω/km
|
5.7
9.4
8.2
|
|
Mutual capacitance
|
pF/m
|
100
|
|
Characteristic impedance
|
Ω
|
50 ± 2
|
|
Velocity ratio
|
0.66
|
|
Maximum operating frequency
|
11 GHz
|
|
Attenuation at
|
|
1 MHz
10 MHz
20 MHz
100 MHz
400 MHz
1000 MHz
2000 MHz
3000 MHz
10000 MHz
|
dB/100m
|
0.82
2.6
3.7
8.5
17.6
28.8
42.4
53.4
110.5
|
|
Maximum Power rating at (ambient + 25°C)
|
|
1 MHz
10 MHz
20 MHz
100 MHz
400 MHz
1000 MHz
2000 MHz
3000 MHz
10000 MHz
|
Watts
|
5317
1672
1178
518
251
154
105
83
41
|
|
Operating voltage
|
kVrms
|
3.7
|
|
Test voltage
|
kVrms
|
10.0
|
|