Image

Armoured industrial cable
AICI-I/O/RM-W

Indoor and outdoor
Flame retardant and halogen free
Steel wire braiding
Tight buffer

Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel, petrol, glycol, etanol, white spirite and ASTM oil 2. The resistance to these fluids is according to DOD-STD-1678, method 8030. The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 mm tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type.
 

Weight and dimensions

Number of fibres

Secondary coating
[mm]

Outer diameter
[mm]

Weight
[kg/km]

Tensile strength*
[Inst./oper.]
[N]

2

0.9

7.8

100

400/175

4

0.9

8.2

110

700/250

8

0.9

9.4

125

800/350

12

0.9

10.4

145

1200/500

24

0.9

12.0

180

1700/750

Cable properties

*Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation

 

See above
See above

 

Temperature window
Operation
Installation
Storage

-40°C to +70°C
-10°C to +70°C
-40°C to +70°C

Crush (IEC 60794-1-2E3)

2000 N/10cm

Water tightness* (IEC 60794-1-2F5B)

< 3 m/24 hours

Impact (IEC 60794-1-2E4)

1 impacts, 25J

Fire and smoke classifications

Torsion (IEC 60794-1-2E7)

±1 turn/1m

IEC 60332-1

 

Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Flexibility (IEC 60794-1-2E8)

15x outer diameter

<0.5 dB/ ±5 turn
1000 cycles

IEC 60332-3-22

IEC 60332-3-24
IEC 61034
IEC 60754-1
IEC 60754-2

Ordering information

Part no.

Cable code

Part no.

Cable code

Part no.

Cable code

695410

G2-9/125 AICI-I/O/RM-W

695412

G2-50/125 AICI-I/O/RM-W

695414

G2-62.5/125 AICI-I/O/RM-W

695420

G4-9/125 AICI-I/O/RM-W

695422

G4-50/125 AICI-I/O/RM-W

695424

G4-62.5/125 AICI-I/O/RM-W

695440

G8-9/125 AICI-I/O/RM-W

695442

G8-50/125 AICI-I/O/RM-W

695444

G8-62.5/125 AICI-I/O/RM-W

695450

G12-9/125 AICI-I/O/RM-W

695452

G12-50/125 AICI-I/O/RM-W

695454

G12-62.5/125 AICI-I/O/RM-W

695480

G24-9/125 AICI-I/O/RM-W

695482

G24-50/125 AICI-I/O/RM-W

695484

G24-62.5/125 AICI-I/O/RM-W

 

 
 
 
 
 